Gongyi Xinqi Polymer Co., Ltd.Water Treatment FlocculantWATER CLARIFICATION WORKBOOK
DEFINE → TEST → SETTLE → VERIFY
REQUEST A WATER TEST SET →
GRADE SCREEN 01 / ANIONIC

Anionic Water Treatment Flocculant

Evaluate anionic water treatment flocculant for mineral suspensions, coagulant-aid service and clarification using representative water and separator evidence.

SAMPLE
process state
POLYMER
matched preparation
RESULT
separator evidence
White powder, polymer emulsion and prepared water treatment flocculant solution on a laboratory bench
GRADE SCREEN 01 / ANIONIC
DOSSIER INDEX01Define the water and separation duty02Preserve a representative sample03Screen ionic profile and form04Normalize preparation and dose05Measure the complete treatment result06Release a bounded operating window
01

Define the water and separation duty

State the source water, mineral particles, hydroxide floc and surface charge after coagulation, coagulant sequence, separator and downstream process before comparing polymers.

A product that works in one water cannot be assumed to transfer to another turbidity, mineral or hydraulic condition.

02

Preserve a representative sample

Record sampling point, operating state, pH, temperature, turbidity or suspended solids, alkalinity, conductivity and upstream chemicals.

Mix the bulk sample consistently before splitting jars and retain the untreated reference.

03

Screen ionic profile and form

Compare coded anionic, cationic and nonionic candidates across plausible molecular ranges and powder or emulsion forms.

Charge information narrows the screen; measured clarification and downstream response decide the result.

04

Normalize preparation and dose

Keep active basis, stock concentration, water quality, aging, addition order and complete powder hydration or emulsion inversion consistent for every candidate.

Unequal make-down or dose conversion invalidates a supplier comparison.

05

Measure the complete treatment result

Track settling velocity, supernatant turbidity, sludge compaction and filter response, floc strength, separation rate, clarified-water quality, sludge volume and filter consequences.

Large visible floc is not sufficient if it breaks, carries over or shortens the filter run.

06

Release a bounded operating window

Link product code, lot, raw-water condition, dose basis, mixing, measurements, COA, SDS, packaging and quotation.

Revalidate after a meaningful water-source, coagulant, equipment, preparation or product change.

WhatsAppEmail